Release Notes - RepeaterNet Craft 2.7.1 ================================ Changes in this version --------------------------------- 1 - New P/N added for RC1920 Added new P/N for RC19-2X15 900-1901-00 RC19-2X15 A Block 900-1902-00 RC19-2X15 B Block 900-1903-00 RC19-2X15 C Block 900-1904-00 RC19-2X15 D Block 900-1905-00 RC19-2X15 E Block 900-1906-00 RC19-2X15 F Block These P/N can only be assigned with Firmware Family 91-XX-XX Added new P/N for RC19-1X15 900-1311-00 RC19-1X15 A Block 900-1312-00 RC19-1X15 B Block 900-1313-00 RC19-1X15 C Block 900-1314-00 RC19-1X15 D Block 900-1315-00 RC19-1X15 E Block 900-1316-00 RC19-1X15 F Block These P/N can only be assigned with Firmware Family 91-XX-XX Added new P/N for RC19-1X10 900-1301-11 RC19-1X10 A Block 900-1302-11 RC19-1X10 B Block 900-1303-11 RC19-1X10 C Block 900-1304-11 RC19-1X10 D Block 900-1305-11 RC19-1X10 E Block 900-1306-11 RC19-1X10 F Block 2 - Display CSF current measurement window when user click on the CSF icon on the all RC19-XX Craft. 3 - Added the default configuration files for RC19-XX repeater to the Craft installation directory. Bug fixed ------------ 1 - Problem Tracker 193 ( PT-193) If the Craft is running at 38400, and a user enters anything except "FL" in LU 1-1-4(Hardware Rev.), the Craft puts up a message saying it is switching to 38400, but it actually switches the PC's serial port to 9600 baud. The repeater remains at 38400, which is correct, because the repeater will only switch to 9600 if "FL" is written to that LU. 2 - Problem Tracker 195 ( PT-195) This problem was seen in Craft 2.6.3 but may still be a problem in Craft 2.7, so that's why I'm including it. When a growth box was selected on a 1900, the Craft was writing part number 3640-18 to the main box, which is not a valid part number. 3 - Problem Tracker 196 ( PT-196) If a 1900 has an invalid part number stored, it will only get LU 1-2-3, but will not get any other LU's, and doesn't allow the user to do much. It should report an error, and allow the user to change the part number. 4 - Problem Tracker 198 ( PT-198) During modem communication a display problem can occur in the measurement windows: 1) Open a measurement window for an extended period of time, and then close the window. 2) Open a different measurement window, and the window will not update until the commands buffered from the first measurement window have been sent to the repeater. 3) The solution appears to be to clear the buffer when a measurement window is closed. 5- Fixed problem on installing Craft 2.7 on a Windows 2000 computer that does not have SP2 installed.